# Site

> See every device at your car wash on one page, test each connection in one click, and debug Coordinator power or heat problems.

## Overview

The Site page lists everything FlexWash installed at one location. Open **Admin > Site**, then select the car wash in the top bar.

| Tab | What it shows |
| :- | :- |
| Devices | Every device at the site, its latest ping result, and the health of the Coordinator. |
| Hardware | Spare and supporting hardware kept at the site. |
| Network | Crosslinks, static hosts and SIM cards. |
| Setup | How lanes, gates and controllers are wired together. |

## Devices

The Devices tab groups devices by where they are used: Coordinators, Lanes, Payment Devices, Receipt Printers, Tunnel and Network. Each card shows the device name and model, its MAC and IP address, and its latest ping result in the bottom right corner.

![The Devices tab with the Coordinator card and the devices of one lane](https://mintcdn.com/flexwash/VOkKubjMGUZprkgW/technical/hardware/site/devices-tab.png?fit=max\&auto=format\&n=VOkKubjMGUZprkgW\&q=85\&s=7ea1728b8c7a7c2b4fec8d5d849533ec)

## Ping Test

A ping test asks a device to answer over the network. A device that answers has power, is connected, and is responding.

FlexWash pings every device automatically, every 30 seconds, while the Devices tab is open. The bar above the cards counts the devices that answered the last ping, failed it, or were not pinged, and shows when the last test ran.

![The ping bar with its reachable, unreachable and not pinged counts and the Ping now button](https://mintcdn.com/flexwash/VOkKubjMGUZprkgW/technical/hardware/site/ping-bar.png?fit=max\&auto=format\&n=VOkKubjMGUZprkgW\&q=85\&s=1867833315029fea41a4218394f6a548)

### Run a ping test

**1. Open the Devices tab**

Open **Admin > Site** and select the car wash.

**2. Click Ping now**

Each card shows **pinging…** while the test runs. The test takes a few seconds.

**3. Read each card**

The result is in the bottom right corner of each card. Hover over it for details.

To test one device, open the menu on its card and click **Ping**.

### Read the result

| Result | Meaning |
| :- | :- |
| `12 s ago` | The device answered. The time is when it last answered. |
| `unreachable · 3 h ago` | The device did not answer. The time is when it last answered. A device that has never answered reads `unreachable`. |
| `not pinged` | FlexWash did not test the device, for example because it is disabled or not fully set up. Hover over the result for the reason. |

![Two card footers: one device answered seconds ago, the other is unreachable](https://mintcdn.com/flexwash/VOkKubjMGUZprkgW/technical/hardware/site/ping-results.png?fit=max\&auto=format\&n=VOkKubjMGUZprkgW\&q=85\&s=1d780da938b87ca3cee725f0b45babfe)

> [!NOTE]
>
> If the Coordinator is unreachable, every device it tests also reads as unreachable. Restore the Coordinator first. Pay terminals and pay tablets are tested separately.

### If a device is unreachable

1. Confirm the device has power.
2. Confirm its network cable is seated at both ends and the switch port light is on.
3. Click **Ping now** again.
4. If it is still unreachable, follow [Network Issues](https://docs.flexwash.com/technical/troubleshooting/network-issues.md) or [On Prem Issues](https://docs.flexwash.com/technical/troubleshooting/prem-issues.md), or [contact support](https://docs.flexwash.com/technical/troubleshooting/contact-support.md).

## Coordinator Health

The active Coordinator card reports the condition of its own hardware under **Health**, in three tiles: Power, Temperature and Fan. Power is checked every 5 seconds. Temperature and fan speed are checked every 2 minutes. Each tile also charts the last 48 hours, so there is always a full open day to compare against. Hover over a chart for the time and value.

![The Health section of a healthy Coordinator with its Power, Temperature and Fan charts](https://mintcdn.com/flexwash/VOkKubjMGUZprkgW/technical/hardware/site/coordinator-health.png?fit=max\&auto=format\&n=VOkKubjMGUZprkgW\&q=85\&s=3b1fa937edd1c4f8e97b009b0c15a6e0)

| Status | Meaning |
| :- | :- |
| Healthy | Power, temperature and fan are normal. Nothing to do. |
| Power fault | The Coordinator is not getting stable power and has slowed itself down. See [Power fault](#power-fault). |
| Recent power faults | Power is stable now, but short faults occurred in the last 48 hours. See [Power fault](#power-fault). |
| Hot | The Coordinator is at 90 °C or above. It still runs at full speed. See [Overheating](#overheating). |
| Overheating | The Coordinator is at 95 °C or above. It slows itself down to cool off. See [Overheating](#overheating). |
| Fan stopped | The cooling fan reports 0 RPM. See [Fan stopped](#fan-stopped). |
| Not reported | This Coordinator model does not have that sensor. Nothing to do. |
| Not available | The Coordinator sent no health report. It is offline, or its software does not report health yet. Check the Coordinator's ping result. |

When a Coordinator restarts, its Health section reads **Starting** until its first readings arrive, within 2 minutes.

### Power fault

A power fault means the Coordinator is not getting stable power. It slows itself down until power is stable again, so plate reads, gate opens and checkouts can lag or time out. This is a power problem, not a heat problem. The usual cause is a failing, loose or underpowered power adapter.

**Recent power faults** means power is stable right now, but the Coordinator reported short faults in the last 48 hours. Each one slows the Coordinator for a few seconds. Faults that keep coming back usually mean the power adapter is failing or its outlet is overloaded.

![The Power tile showing a power fault, with its explanation open](https://mintcdn.com/flexwash/VOkKubjMGUZprkgW/technical/hardware/site/power-fault.png?fit=max\&auto=format\&n=VOkKubjMGUZprkgW\&q=85\&s=e23808eb9fad6e4d4c4b9d33b9581556)

What to do, for either status:

1. Reseat the power cable at both ends.
2. Confirm the Coordinator is plugged into the FlexWash power supply and non-FlexWash equipment shares it.
3. If the fault returns, [contact support](https://docs.flexwash.com/technical/troubleshooting/contact-support.md).

### Overheating

**Overheating** means the Coordinator is at 95 °C or above, close to the limit of its processor. It slows itself down to cool off and can shut down if it gets hotter. **Hot** means it is at 90 °C or above. It still runs at full speed, but it is close to overheating. Hot during business hours is normal, overheating is not.

What to do:

1. Turn off the Coordinator.
2. Use an air blaster to clear out any dirt or dust that has built up inside it.
3. Check where it sits against [Placement and Cooling](#placement-and-cooling).

### Fan stopped

The cooling fan reports 0 RPM. If the temperature is also high, the fan has most likely failed or is blocked.

What to do: turn off the Coordinator and check that nothing is jammed in the
vents.

## Placement and Cooling

The Coordinator and the switch cool themselves with air. Where and how they sit decides whether they stay cool.

* **Coordinator:** keep the vents on its sides **completely unobstructed** so its fans can dissipate heat. Nothing may cover or press against them.
* **Switch:** lay it **horizontally flat** so it can dissipate heat. Do not stand it on its side.
* **Room:** keep both in a climate-controlled room, in an enclosure that stops dust from building up.
* **Cleaning:** if dirt or dust has built up, turn off the Coordinator and clear it out with an air blaster.

![The vents of a Coordinator, marked in blue](https://mintcdn.com/flexwash/VOkKubjMGUZprkgW/technical/hardware/site/coordinator-vents.jpg?fit=max\&auto=format\&n=VOkKubjMGUZprkgW\&q=85\&s=418d6d648888dcf64f2dc0b738b74667)

The Coordinator's vents. Keep them clear.

> [!WARNING]
>
> A Coordinator with blocked vents, or a switch standing on its side, overheats. The photo below shows what not to do.

![What not to do: a dust-covered Coordinator on an open, dusty shelf, wedged between a network switch standing on its side and another device](https://mintcdn.com/flexwash/VOkKubjMGUZprkgW/technical/hardware/site/what-not-to-do.jpg?fit=max\&auto=format\&n=VOkKubjMGUZprkgW\&q=85\&s=9c6b6d904bd69eeaecb95f65c729748f)

## Network Status

The active Coordinator card also shows how the site reaches the internet. **Router** means the site is on its main internet connection. **Cellular** means the main connection is down and the site is running on [Cellular Failover](https://docs.flexwash.com/technical/hardware/cellular-failover.md). See [Network](https://docs.flexwash.com/technical/hardware/network.md) for the full layout of the FlexWash network.

## Related

* [On Prem Issues](https://docs.flexwash.com/technical/troubleshooting/prem-issues.md)
* [Network Issues](https://docs.flexwash.com/technical/troubleshooting/network-issues.md)
* [Network](https://docs.flexwash.com/technical/hardware/network.md)
* [Cellular Failover](https://docs.flexwash.com/technical/hardware/cellular-failover.md)
* [Contact Support from Pay Tablets](https://docs.flexwash.com/technical/troubleshooting/contact-support.md)


This documentation is built and hosted on [Mintlify](https://mintlify.com), a developer documentation platform.